logo
Found 731 results for "

data center uninterruptible power supply

"
Kwaliteit 240KVA 3 fase Visench Fortress 3p3p 240KW OEM stroomvoorziening Online-Ups voor datacenters fabriek

240KVA 3 fase Visench Fortress 3p3p 240KW OEM stroomvoorziening Online-Ups voor datacenters

Product nameFortress 3p3pRated Capacity60KVA-300KVAPower Factor0.99Input Voltage3 x 38014001415 VAC (3Ph+N)Frequency40Hz ~70HzOutput Voltage3 x 38014001415 VAC (3Ph+N)IP ClassIP20Battery TypeExternal BatteryPHASE3-phase in / 3-phase outHarmonic Distortion≤ 2% THD (Linear Load);≤ 4% THD (Non-linear Load)Temperature CompensationYesBattery Mode94.50%Frequency Range46Hz~ 54Hz or 56Hz~ 64HZAltitude**150%for 200msBATTERY/CHARGERNominal Voltage+/-192V~+1-240V (Selectable)Maximum

Kwaliteit R410 Koelmiddel 5000 m3/h Luchtstroom Precision Room-Level Air Conditioner voor Data Center fabriek

R410 Koelmiddel 5000 m3/h Luchtstroom Precision Room-Level Air Conditioner voor Data Center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Kwaliteit 380VAC/50HZ Visench CRA-serie precisieluchtconditioner voor datacenters fabriek

380VAC/50HZ Visench CRA-serie precisieluchtconditioner voor datacenters

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Kwaliteit 8 kW 13 kW Industrieel airconditioner Laboratorium Datacentrum Serverruimte Koeling Alleen categorie fabriek

8 kW 13 kW Industrieel airconditioner Laboratorium Datacentrum Serverruimte Koeling Alleen categorie

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Kwaliteit EC-ventilator Visench CRA-serie 12.5KW precisieklimatisator voor datacenters fabriek

EC-ventilator Visench CRA-serie 12.5KW precisieklimatisator voor datacenters

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Kwaliteit Montage vloer staande industriële airconditioner voor laboratorium serverruimte en datacenter fabriek

Montage vloer staande industriële airconditioner voor laboratorium serverruimte en datacenter

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Kwaliteit Airconditioner met hoge industriële precisie 8KW 13KW voor laboratorium Data Center Server Room fabriek

Airconditioner met hoge industriële precisie 8KW 13KW voor laboratorium Data Center Server Room

Product Description Specification CategoryCooling onlyIndoor unit modelEFA008C1Y0AEFA013C1Y0AOutdoor unit modelECA012ECA019Energy efficiency ratio3.63.45Power Specifications380VAC/50HZIndoor unit maximum current7A12AOutdoor unit maximum current0.85A1.7ARecommended input circuit breaker16A/4P16A/4PIndoor unit cable (recommended)5*2.5mm²5*2.5mm²Outdoor unit cable (recommended)3*1mm²Inner and outer unit signal cables (recommended)noneCooling capacity (kW)813Sensible cooling

Kwaliteit Hoog veiligheidsniveau Visench CRA 12.5KW 25KW 40KW 50KW 60KW Industrieel precisieklimatologisch toestel voor datacenters fabriek

Hoog veiligheidsniveau Visench CRA 12.5KW 25KW 40KW 50KW 60KW Industrieel precisieklimatologisch toestel voor datacenters

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible

Kwaliteit 5000m3/h Visench CRA 12.5KW Serverruimte Precision Airconditioner voor Lab Data Center fabriek

5000m3/h Visench CRA 12.5KW Serverruimte Precision Airconditioner voor Lab Data Center

CRA series room-level precision air conditioner technical parameters and configuration table (row level)Air conditioner typeSingle cooling typeConstant temperature and humidity typeIndoor unit modelCRA025HAIT00CRA025HAITNNCRA040HAITNNOutdoor unit modelECA033ECA033ECA033Energy efficiency ratio2.82.83.02Power Specifications380VAC/50HZMaximum current20A23.6A40ARecommended input space32A/4P40A/4P64A/4PCooling capacity (kw)252540.3Sensible cooling capacity (kw)252540.3sensible