three phase online ups
"
Visench Giant iNDll 33-40k 40KVA Industrial Supply Power 40KW 40000VA 40000W Online PF 1 UPS Voor netwerken
Product nameGiant iND IIRated Capacity10kva-160kvaRectifier Type6 pulse / 12 pulsePower Factor0.9, customized up to 1.0Input Voltage380VACI400VACI415VACFrequency50Hz/60Hz + 10%Output Voltage380VACI400VACI415VACTVSS40KAFrequency50Hz/60Hz± 1%Altitude1000mSafetyIEC62040-1-2017Battery Voltage384 VDC (Adjustable)Cold StartYesDry Contacts5 outputs and 4 inputsIP ProtectionIP31 (default), IP42 (optional)Operating Temperature0~ 40°CSize(mm)800 x 800 x 1800Weight(Kgs)349/385/427/508
160KVA Visench Giant iNDll 33-160k 160KVA Industrial Supply Power 160KW 160000VA 160000W Online UPS Voor computer/netwerken
Product nameGiant iND IIRated Capacity10kva-160kvaRectifier Type6 pulse / 12 pulsePower Factor0.9, customized up to 1.0Input Voltage380VACI400VACI415VACFrequency50Hz/60Hz + 10%Output Voltage380VACI400VACI415VACTVSS40KAFrequency50Hz/60Hz± 1%Altitude1000mSafetyIEC62040-1-2017Battery Voltage384 VDC (Adjustable)Cold StartYesDry Contacts5 outputs and 4 inputsIP ProtectionIP31 (default), IP42 (optional)Operating Temperature0~ 40°CSize(mm)800 x 800 x 1800Weight(Kgs)349/385/427/508
Giant iND ll OEM UPS Industrial Supply Online UPS stroomvoorziening voor hoge stroomvraag
Product nameGiant iND IIRated Capacity10kva-160kvaRectifier Type6 pulse / 12 pulsePower Factor0.9, customized up to 1.0Input Voltage380VACI400VACI415VACFrequency50Hz/60Hz + 10%Output Voltage380VACI400VACI415VACTVSS40KAFrequency50Hz/60Hz± 1%Altitude1000mSafetyIEC62040-1-2017Battery Voltage384 VDC (Adjustable)Cold StartYesDry Contacts5 outputs and 4 inputsIP ProtectionIP31 (default), IP42 (optional)Operating Temperature0~ 40°CSize(mm)800 x 800 x 1800Weight(Kgs)349/385/427/508
Riello Multi Sentry 160KVA Driefasige UPS met dubbele conversie voor telecommunicatie
Riello Multi Sentry 160KVA 3-fase online UPS voor telecom. Beschikt over een arbeidsfactor van 0,99, ≤3% THDI, brede spanningstolerantie (400V ±20%) en robuuste overbelastingscapaciteit (125% gedurende 60 min). Meerdere batterijopties (VRLA AGM/GEL/NiCd) en uitgebreide communicatie-interfaces.
Riello Multi Sentry 200KVA Driefasige UPS met dubbele conversie voor telecommunicatie
Riello Multi Sentry 200KVA 3-fase online UPS voor datacenters. Beschikt over een arbeidsfactor van 0,99, ≤3% THDI, 125% overbelastingscapaciteit en meerdere batterijopties (VRLA AGM/GEL/NiCd). Robuuste IP20-bescherming met geavanceerde communicatie-interfaces.
Visench Arena 3/3-10k 10000VA/10000W 3U 10KVA 10KW voor beveiligings- / bewakings- / alarmsysteem
Product nameArena 3U Online UPSPHASE3 phase in/3 phase outInput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Power Factor≥0.99 @100%loadOutput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Current Crest Ratio3:1 (max.)WaveformPure SinewaveOperating Humidity0-95%RH @0-40°℃(non-condensing)Dimension,DxWxH(mm)678x418x129 [3U]Net Weight (kgs)20.5/17.6/21Frequency Range46~54Hz or 56~64HzHarmonic Distortion≤2%THD (Linear Load);≤3%THD (Non-linear Load)Inverter to BypasszeroCAPAC
10KVA 6KVA 3KVA Pure Sinewave 360v/380v/400v/415v OEM UPS stroomvoorziening door Visench Arena
Product nameArena 3U Online UPSPHASE3 phase in/3 phase outInput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Power Factor≥0.99 @100%loadOutput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Current Crest Ratio3:1 (max.)WaveformPure SinewaveOperating Humidity0-95%RH @0-40°℃(non-condensing)Dimension,DxWxH(mm)678x418x129 [3U]Net Weight (kgs)20.5/17.6/21Frequency Range46~54Hz or 56~64HzHarmonic Distortion≤2%THD (Linear Load);≤3%THD (Non-linear Load)Inverter to BypasszeroCAPAC
Visench Arena 3U Pure Sinewave OEM UPS 10KVA 6KVA 3KVA voor beveiliging/bewaking/alarm
Product nameArena 3U Online UPSPHASE3 phase in/3 phase outInput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Power Factor≥0.99 @100%loadOutput Voltage3x360VAC/380VAC/ 400VAC/415VAC (3Ph+N+PE)Current Crest Ratio3:1 (max.)WaveformPure SinewaveOperating Humidity0-95%RH @0-40°℃(non-condensing)Dimension,DxWxH(mm)678x418x129 [3U]Net Weight (kgs)20.5/17.6/21Frequency Range46~54Hz or 56~64HzHarmonic Distortion≤2%THD (Linear Load);≤3%THD (Non-linear Load)Inverter to BypasszeroCAPAC